| industry centers products literature support news about us trade shows contact home |
|
![]() |
|||||||||||||||||
V-Cone Flow Meter With Built-In Conditioner Fits in Tight Muni Surface Water Installations
Municipal water engineers tasked with measuring liquid flow from water storage reservoirs or lakes as it enters treatment facilities will find the space-saving V-Cone® Flow Meter from McCrometer easily fits in crowded equipment installations where long pipe straight-runs are impractical. McCrometer’s compact V-Cone Flow Meter features built-in flow conditioning. It reduces flow meter straight pipe run requirements by up to 70 percent or more and needs only 0-3 straight pipe diameters upstream and 0-1 downstream to operate effectively. The resulting savings (after installation) in plant real estate, materials and labor costs can actually exceed the cost of the instrument itself. Featuring reliable differential pressure technology, the V-Cone Flow Meter offers excellent accuracy and repeatability over a wide flow range. It operates over a flow range of 10:1 with low head loss and supports line sizes from 0.5 to greater than 120 inches. Accuracy is ±0.5%, with a repeatability of ±0.1%. Municipal water engineers can rely on the V-Cone Flow Meter for consistent performance and low cost of ownership because it requires virtually no recalibration or maintenance over a long life exceeding 25 years. The versatile V-Cone is also easy to install, making it ideal for water plant expansions or retrofits as well as new facilities. The V-Cone’s unique no-moving parts design provides built-in flow conditioning, which nearly eliminates the upstream/downstream straight pipe runs required by nearly all flow meter technologies. Typical flow meter installations may require 10 to more than 40 straight pipe diameters upstream from the meter and 5 or more straight pipe diameters downstream to eliminate the effects of swirl and other pipeline disturbances caused by elbows, valves and other devices that decrease measurement accuracy. In comparison to traditional instruments such as magnetic and venturi flow meters, the V-Cone’s design is inherently more accurate because the flow conditioning function is built-into the basic instrument. The V-Cone conditions fluid flow to provide a stable flow profile that increases accuracy. It features a centrally-located cone inside a tube. The cone interacts with the fluid flow and reshapes the velocity profile to create a lower pressure region immediately downstream. The pressure difference, which is exhibited between the static line pressure and the low pressure created downstream of the cone, can be measured via two pressure sensing taps. One tap is placed slightly upstream of the cone and the other is located in the downstream face of the cone itself. The pressure difference can then be incorporated into a derivation of the Bernoulli equation to determine the volumetric fluid flow rate. |
year 2009 news releases
V-Cone for
Mc Propeller for
McCrometer
V-Cone for
EA631 Transmitter
weight-saving |
|||||||||||||||||
|
©2006-2011 McCrometer,
Inc. | 3255 West Stetson Avenue, Hemet, CA 92545
USA | +1-951-652-6811 | Fax
+1-951-652-3078 |